Annals of Thoracic Medicine Official publication of the Saudi Thoracic Society, affiliated to King Saud University
 
Search Ahead of print Current Issue Archives Instructions Subscribe e-Alerts Login 
Home Email this article link Print this article Bookmark this page Decrease font size Default font size Increase font size
ORIGINAL ARTICLE
Year : 2007  |  Volume : 2  |  Issue : 4  |  Page : 148-153

Exploring measurement biases associated with esophageal Doppler monitoring in critically ill patients in intensive care unit


Department of Surgery, Division of Traumatology and Surgical Critical Care, University of Pennsylvania School of Medicine, 3440 Market Street, 1st Floor, Philadelphia, PA 19104-3335, USA

Correspondence Address:
Peter S Stawicki
Department of Medicine, King Khalid National Guard Hospital, P. O. Box: 9515, Jeddah 21423, Saudi Arabia

Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1817-1737.36548

Rights and Permissions

Background : Esophageal Doppler monitoring (EDM) is utilized in numerous clinical settings. This study examines the relationship between pulmonary artery catheter (PAC) and EDM-derived hemodynamic parameters, concentrating on gender- and age-related EDM measurement biases. Materials and Methods : Prospective study of EDM use in ventilated surgical ICU patients. Parameters examined included demographics, diagnosis, resuscitation endpoints, cardiac output (CO) and stroke volume from both devices, number of personnel and time needed to place equipment, time to data acquisition, duration of use, complications of placement. Results : Fifteen patients (11 men, 4 women, mean age 47 years) were included. Most common diagnoses included trauma (7/15) and sepsis (4/15). Insertion time and time to data acquisition were shorter for EDM than for PAC ( P <0.001). The EDM required an average of 1.1 persons to place (2.4 for PAC, P =0.002). Mean EDM utilization time was 12.4 h. There was a fair CO correlation between EDM and PAC (r = 0.647, P <0.001). Overall, the EDM underestimated CO relative to PAC (bias -1.42 ± 2.08, 95% CI: -5.58-2.74), with more underestimation in women (mean bias difference of -1.16, P <0.001). No significant age-related measurement bias differences between PAC and EDM were noted. Significant reductions in lactate and norepinephrine requirement were noted following EDM monitoring periods. Conclusions : This study found that the EDM significantly underestimated cardiac output in women when compared to PAC. Clinicians should be aware of this measurement bias when making therapeutic decision based on EDM data. Significant reductions in lactate and norepinephrine requirement during EDM monitoring periods support the clinical usefulness of EDM technology.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed7243    
    Printed318    
    Emailed0    
    PDF Downloaded727    
    Comments [Add]    
    Cited by others 6    

Recommend this journal