ORIGINAL ARTICLE
Year : 2016  |  Volume : 11  |  Issue : 3  |  Page : 214-218

Nuss procedure: Technical modifications to ease bending of the support bar and lateral stabilizer placement


Department of Pediatric Surgery, Dokuz Eylül University, Medical School, Izmir, Turkey

Correspondence Address:
Osman Zeki Karakus
Department of Pediatric Surgery, Dokuz Eylul University, Medical School, 35340 Balcova, Izmir
Turkey
Login to access the Email id


DOI: 10.4103/1817-1737.185758

PMID: 27512512

Rights and Permissions

Background: Modifications defined to ease bending of the support bar and lateral stabilizer placement during minimal invasive repair of pectus excavatum (MIRPE) have not been reported. We herein report our experience with MIRPE including several technical modifications. Methods: A total of 87 patients who underwent MIRPE were evaluated retrospectively. Technical modifications are (1) a template drawn preoperatively according to the anthropometric measurements, (2) more laterally placed thoracal incisions, (3) single existing incision for multiple support bars, (4) to secure lateral stabilizers to support bar in inverted position. Results: The mean patient age was 11.2 ± 3.8 years. The mean operating time was 63.7 ± 18.7 min. The mean Haller index was 5.4 ± 2.1. Eight patients necessitated two support bars. The support bars were removed in 69 patients after the completion of treatment. Support bars were left in place 26.8 ± 4.3 months. Final chest contours of the 56 patients were evaluated as 12 months passed after support bar removal and excellent repair results were determined in 84.2%. Conclusion: Preoperative bending of the support bar according to anthropometric measurements and fixation of the lateral stabilizers to the support bar in inverted position facilitates bar shaping and lateral stabilizer placement.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2298    
    Printed51    
    Emailed0    
    PDF Downloaded267    
    Comments [Add]    

Recommend this journal