Annals of Thoracic Medicine Official publication of the Saudi Thoracic Society, affiliated to King Saud University
 
Search Ahead of print Current Issue Archives Instructions Subscribe e-Alerts Login 
Home Email this article link Print this article Bookmark this page Decrease font size Default font size Increase font size
ORIGINAL ARTICLE
Year : 2009  |  Volume : 4  |  Issue : 4  |  Page : 182-186

Autologous blood pleurodesis: A good choice in patients with persistent air leak


1 Department of Chest Surgery, University of Yuzuncu Yil, Turkey
2 Department of Pediatric Surgery, University of Yuzuncu Yil, Turkey

Correspondence Address:
Ufuk Cobanoglu
Department of Chest Surgery, University of Yuzuncu Yil, Arastirma Hastanesi Bashekimlik - 651 00, Van
Turkey
Login to access the Email id


DOI: 10.4103/1817-1737.56011

PMID: 19881163

Rights and Permissions

Aim: The study compares the efficiency, side effects and complications of autologous blood pleurodesis with talcum powder and tetracycline. Materials and Methods: This prospective study evaluated 50 patients with persistent air leak resulting from primary and secssondary spontaneous pneumothorax between February 2004 and March 2009. The patients inclussded 32 (64.0%) males and 18 (36.0%) females with a median age of 39 years (range 14-69 years). All cases had persistent air leak of more than seven days. Pleurodesis was performed using autologous blood in 20 (40.0%) patients, talc powder in 19 (38.0%) patients and tetracycline in 11 (22.0%) patients through a chest tube. Air leak cessation times after pleurodesis, side effects and pulmonary function tests (PFT) in the first and third months were measured. Results: Recurrent primary spontaneous pneumothorax was the cause of persistent air leak in all cases. Air leaks were expiratory only in 54.0% of cases. We obtained a success rate of 75.0% using autologous blood, 84.2% using talc powder and 63.6% using tetracycline. Mean air leak termination interval was significantly (P < 0.001) shorter in patients treated with autologous blood in comparison to talc powder and tetracycline. We observed a significant (P < 0.05) decline in PFT in patients treated with talc powder compared with tetracycline and autologous blood. Vital capacity, FVC and FEV1 were significantly lower in patients treated with tetracycline compared with autologous blood. Conclusion: This study shows that autologous blood pleurodesis compared to talc powder and tetracycline is related with shorter leak cessation time and less pulmonary function decline in patients with persistent air leak. We think further randomized clinical trials of pleurodesis as treatment could increase its use in thorax surgery by demonstrating the safety and the efficacy of this procedure.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed7308    
    Printed287    
    Emailed3    
    PDF Downloaded1064    
    Comments [Add]    
    Cited by others 8    

Recommend this journal